| S-land seismic instrument |
S-land seismic instrument product information s. geophone Role 1. Signal conditions and the seismic signal of the data 2. Detection of a seismic wave and the operation of electronic components Physical characteristics Light, waterproof, rugged shell Specifications Input impedance: 1 k (without resistance under the conditions of> 25) 5nf Preamplifier gain: 1 db, 12db, 24db, 36db All the input level specifications: 0 db 5vpp 12db 1.25vpp 24db 312.5mvpp 36db 78.1mvpp Reset: zero gain Sampling intervals: 0.25,0.5,1 ms, 2ms Bandwidth: (-3 db) 428hz Attenuation of guarantee (Ni Kuisi -6 db-wide standard measure under)> 130 db Passband ripple (400 hz below) 0.01 db Passband characteristics: Linear SNR measurement (RMS RMS800 OHM to the termination of the input) 0db 123db (typ)> 120db 12db 122db (typ)> 118db 24db 115db (typ)> 112db 36db 103db (typ)> 100db Total harmonic distortion (-6 db-wide under the measurement specifications, 31.25 hz) 0db 115db (typ)> 110db 12db 110db (typ)> 100db 24db 115db (typ)> 112db 36db 100db (typ)> 90db Gain accuracy: (absolute) 1% (typical) Gain accuracy: (different gain the relative few) 0.4% (typical) Power consumption: 250 mw (typical) Operating temperature: -40 to 75 degrees s.line interface module (slim) Role 1. Control two geophone strings 2. Transmission of data from the detector to the central records unit. Physical characteristics Waterproof aluminum shell 7x2.7x2in (119x69x50mm) Specifications Data transfer rate: 100 mb / s Data record: - Operating temperature: -40 to 75 degrees s. seismic wave-string (SGS) Role 1. Connected through the square stranding 12 seismic wave devices to a geophone strings Physical characteristics The deduction through a metal D-ring connection, the assembly of the transport and deployment of simple and easy. Surge battery unit (BBU) Role 1. Change the battery voltage from 12 V to 24 V 2 for a cable assemblies (4 SLIMS) Physical characteristics Waterproof aluminum shell 5.3x2.7x2in3.1 (135x69x79mm) Specifications The battery voltage: Enter the 12 V (with fuses) Battery connector: 2 hot-swappable enter Operating temperature: -40 to 75 degrees Cross intelligence unit (IXU) Role 1. To control the distribution and number of lines 2. From the number of transit lines and concentrate on the real-time data Physical characteristics Waterproof aluminum shell 10.25x9.5x2.5in (260x241x65mm) Specifications Power consumption: 6 W (typical) The largest production capacity 7000 channel 1 ms 14,000 channel 2 ms Operating temperature: -40 to 75 degrees Center records unit (CRU) Role 1. Master clock system 2. Resource control interface 3.4AUX channel (optional) 4. Real-time processing Physical characteristics Waterproof aluminum shell 10.25x9.5x2.5in (260x241x65mm) Specifications Master clock precision: better than 5 PPM Resources began: Isolation (high / low) Cut off time: isolation (high / low) Time to cut off the resolution: 1 / 1024 ms Operating temperature: 75 degrees -0 Projects targeted High-resolution reflection and refraction seismic stratigraphy investigation. Application of the wide range of earthquake engineering Geological survey technology, such as the building of regional geological / rock hardness evaluation / rock detection Hydro-geological studies, such as groundwater find, underground mineral resources, exploration of geothermal water Environmental Investigation (waste dump sites determine the scope, containing scrap heap of pollutants close to the permeability of the soil) The assessment of natural hazards, such as tilting the surface of the bedrock description Raw materials such as gravel quarries layer, iron ore exploration of the rock Basic configuration The largest 36, 0.25,0.5 sampling rate and 1 msec Advanced Configuration The largest 144, 0.25,0.5 sampling rate and 1 msec Mining applications High-resolution 2 - D and 3 - D seismic reflection investigation Application of the area is in a more broad range of mining seismology, View of coal and positioning map Mining operations and the formulation of plans The detection of copper and molybdenum, the detection Deposits of detection 2-D basic configuration 400, the second sampling rate of 1 trillion 2-D advanced configuration Typical 1000, the second sampling |
See more products from this supplier.
Do you want to show products of your own company? Join FREE now!